Total Data Centre Energy Consumption (EDC)

Total energy used inside the data centre boundary across IT equipment, cooling, power distribution, lighting, and building services. EDC represents the overall energy demand of the total facility. 

Energy Consumed by IT Equipment (EIT)

Energy consumed directly by servers, storage, and network devices. This represents productive workload energy. 

Electricity Consumed by Cooling Systems (E-Cooling)

Energy used by all mechanical and electrical cooling systems, including chillers, CRACs, pumps, and fans, to maintain safe operating temperatures. 

Backup Generator Energy Contribution (EDC-BG)

Energy produced by onsite backup generators. 

Backup Generator Fuel Consumed (BGFC)

The total volume of fuel consumed by backup generators 

Electricity for Thermal Upgrading of Waste Heat (EHEAT)

Electrical energy consumed by heat pump systems to raise recovered waste heat to a temperature suitable for reuse in heating applications such as district heating networks. 

Thermal upgrading

The use of a heat pump to raise recovered waste heat to a temperature suitable for a target application. Required when the Average Waste Heat Temperature (TWH) falls below the threshold needed by the receiving system. 

Waste heat

Thermal energy produced as a by-product of IT equipment operation that is not used productively. Captured via heat exchangers, rear-door coolers, or direct liquid cooling and reported under WHE and ERF when reused externally or internally. 

Total Water Consumption (WIN)

Total volume of water consumed by the data centre. 

Potable Water Usage (WIN-POT)

Volume of drinking‑quality water used by the data centre. 

Non-Industrial Water Consumption (WRE-NID)

The volume of non-potable water drawn into the facility from external alternative sources — such as rainwater harvesting, greywater collection, or reclaimed surface water 

Rainwater harvesting

The collection and storage of rainwater from rooftops or other surfaces for reuse within the facility. When used in cooling systems, harvested rainwater is a non-potable alternative water source counted under WIN-NID. 

Reclaimed water

Water that has been treated and recovered from wastewater streams for reuse in non-potable applications such as cooling tower make-up. Classed as an alternative water source and counted under WIN-NID. 

Capacity & Demand Metrics

Confidence in IT Capacity (Capacity Confidence Rating)

A qualitative indicator showing whether current compute, storage, and network capacity can meet forecast demand without service risk. 

Incoming Data Traffic (TIN)

The total volume of data received by the data centre over the reporting period, captured across all inbound network connections into the facility’s computer room. 

Outgoing Data Traffic (TOUT)

The total volume of data transmitted out of the data centre over the reporting period, captured across all outbound netw cork connections from the facility’s computer room. 

Incoming Traffic Bandwidth (BIN)

The total provisioned capacity for receiving data into the data centre computer room. Calculated by aggregating contracted bandwidth across all active inbound network connections. 

Outgoing Traffic Bandwidth (BOUT)

The total provisioned capacity for transmitting data from the data centre computer room. Calculated by aggregating contracted bandwidth across all active outbound network connections. 

Data Stored and Processed (DSP)

The amount of data retained and actively processed by IT systems. 

ICT Server Capacity (CSERV)

The total performance of all servers, calculated by summing their active state performance values based on EU Regulation 2019/424. Values can be derived from declared data, interpolation, manufacturer inputs, or recognised estimation methods. 

ICT Storage Capacity (CSTOR)

The total installed raw storage capacity available across all storage systems. 

Petabyte (PB)

A unit of digital data equal to one million gigabytes or 10¹⁵ bytes. Used in Report Zero to express data traffic volumes (TIN, TOUT) and storage capacity (CSTOR) at scale. 

Server Efficiency Rating Tool (SERT)

A benchmark developed by SPEC for measuring server energy efficiency across a range of workload levels. Used in ISO 30134 as a basis for aggregating and normalising compute capacity figures in metrics such as CSERV. 

Rated IT Load (PDIT)

The maximum continuous electrical power capacity that the data centre’s electrical and mechanical infrastructure is designed to deliver to IT equipment under normal operating conditions. 

Available Power in the Data Centre (APDC)

The total electrical power capacity currently unallocated and available for new IT load. 

Available Energy in the Data Centre (AEDC)

The total energy that can be consumed over a given reporting period before reaching the contracted or physical limit of the facility’s power supply. 

IT load

The electrical power drawn directly by IT equipment: servers, storage arrays, and networking hardware. Excludes power consumed by facility support systems such as cooling, lighting, and power conditioning. The primary denominator in PUE, CUE, and WUE. 

Efficiency & Performance Metrics

Power Usage Effectiveness (PUE)

A ratio comparing total facility energy use to IT energy use. 

Cooling Efficiency Ratio (CER)

A measure of how effectively cooling systems convert input energy into useful cooling output.  

Cooling Load Factor (CLF)

The proportion of total site energy consumed by cooling systems. 

Water Usage Effectiveness (WUE)

A measure of how much water is used per unit of IT energy consumption. 

Renewable Energy & Heat Reuse

Renewable Energy Factor (REF-ISO)

The share of a data centre’s total energy consumption that is supplied by renewable sources from the grid. 

Green Energy Coefficient (GEC)

A portfolio‑level metric showing the proportion of renewable or low‑carbon energy used across multiple data centre sites. 

Total Renewable Energy Consumption (ERES-TOT)

The total amount of renewable energy consumed. 

Renewable Energy from Guaranties of Origins (ERES-GOO)

The quantity of electricity consumption matched with Guarantee of Origin certificates over the reporting period. GOOs confirm that an equivalent volume of electricity was produced from renewable sources. Certificates are procured separately from physical electricity supply. 

Renewable Energy from Power Purchase Agreements (ERES-PPA)

Renewable electricity sourced through long-term Power Purchase Agreements directly contracted with specific renewable generation assets. PPA-backed energy includes verified certificates of renewable origin. 

Renewable Energy from On-Site Generation (ERES-ON)

Electricity generated directly at the facility from renewable sources. 

Renewables from the Grid (GRID-RENEW)

Renewable electricity drawn from the national or regional grid rather than generated on-site or from Power Purchase Agreements. 

Guaranties of Origins Emissions factor (ERES-GOO-EF)

The carbon emission factor applied to renewable electricity matched with Guarantee of Origin certificates. 

Power Purchase Agreements Emissions factor (ERES-PPA-EF)

The carbon emission factor applied to renewable electricity sourced via Power Purchase Agreements. 

On-Site Generation Emissions factor (ERES-OS-EF)

The carbon emission factor applied to renewable electricity sourced from On-Site Generation. 

Guarantee of Origin (GOO)

An electronic certificate confirming that one megawatt-hour of electricity was produced from a renewable source. Consumers purchase GOOs to make market-based renewable energy claims independent of physical electricity delivery. Counted under ERES-GOO in Report Zero. 

Power Purchase Agreement (PPA)

A long-term contract between an energy buyer and a renewable generator fixing the price and quantity of electricity to be supplied. PPAs support new renewable capacity development and allow buyers to claim the renewable attributes of the contracted output. Counted under ERES-PPA in Report Zero. 

Energy Reuse Factor (ERF)

The ratio of energy exported from the data centre for productive reuse (EREUSE) to total facility energy consumption (EDC). Measures the degree to which the facility recovers and usefully re-exports its waste heat. 

Waste Heat Reused (ERUSE)

The heat that is used or reused outside of the data centre boundary, and which substitutes partly or totally energy needed outside the data centre boundary. 

Average Waste Heat Temperature (TWH)

The mean temperature of thermal energy recovered from IT equipment or cooling infrastructure and made available for reuse over the reporting period. 

Carbon & Emissions Metrics

Carbon Intensity (CI)

The quantity of CO₂ equivalent emitted per unit of electricity generated, expressed in gCO₂e/kWh. Varies by grid region and time of day depending on the generation mix active on the network. 

Carbon dioxide equivalent (CO₂e)

standardised unit for expressing greenhouse gas emissions. Different gases such as methane and nitrous oxide are converted to their CO₂ warming equivalent using Global Warming Potential factors, enabling all emissions to be reported as a single comparable figure. 

Emission factor (EF)

A coefficient that converts an activity quantity — such as kWh of electricity consumed — into an equivalent quantity of greenhouse gas emissions in kgCO₂e. Published by grid operators, government bodies, and standards organisations. 

Energy Efficiency Directive (EED)

An EU legislative framework requiring member states and large energy consumers to improve energy efficiency and report energy use. Data centres above certain capacity thresholds are subject to mandatory reporting obligations including REF disclosure. 

Coefficient of Performance (COP)

A dimensionless efficiency ratio for heat pumps and refrigeration systems. Calculated as useful heat or cooling output divided by electrical energy consumed. 

GHG Protocol (GHGP)

The Greenhouse Gas Protocol — the globally dominant accounting standard for measuring and reporting corporate greenhouse gas emissions. Defines Scope 1, 2, and 3 categories and specifies both location-based and market-based methods for Scope 2 reporting. 

Carbon Usage Effectiveness (CUE)

The ratio of total carbon emissions to IT energy consumption. 

Scope 1 Emissions (Scope 1)

Direct greenhouse gas emissions from sources owned or controlled by the operator. Scope 1 consists primarily of CO₂e produced by combustion of fuel in backup generators during outage events and scheduled test runs. 

Scope 2 Emissions (Market‑Based) (Scope 2 MB)

Indirect greenhouse gas emissions from purchased electricity, calculated using the emission factors of specific electricity products procured by the organisation — such as PPAs, green tariffs, and GOO certificates. Reflects the impact of procurement decisions on the reported carbon footprint. 

Scope 2 Emissions (Location‑Based) (Scope 2 LB)

Indirect greenhouse gas emissions from purchased electricity, calculated using the average carbon intensity of the local grid at the reporting location. Does not reflect any renewable energy procurement instruments; all consumers on the same grid receive the same emission factor regardless of their contracts 

Electricity consumption for systems that are used exclusively for the thermal upgrading of waste heat from the data centre (EHP)

Energy consumed by heat pump systems to upgrade waste heat recovered from IT equipment to temperatures suitable for reuse 

Average setpoint information technology equipment intake air temperature (Tin-Temp)

A long-term contract between an energy buyer and a renewable generator fixing the price and quantity of electricity to be supplied. PPAs support new renewable capacity development and allow buyers to claim the renewable attributes of the contracted output. Counted under ERES-PPA in Report Zero. 

Grid Mix Renewable Percentage (GRID-MIX-PCT)

The share of electricity from the grid generated from renewable sources, expressed as a percentage. Derived from published grid emissions factors and used in location-based carbon calculations. 

Renewable Energy Factor (REF-EED)

A compliance metric under the EU Energy Efficiency Directive (EED) expressing the proportion of total energy consumption attributable to renewable sourcesincludes energy backed by Guarantees of Origin (GOOs) or Power Purchase Agreements (PPAs). 

Total Carbon Emissions (Scope 1 + Scope 2)

The combined greenhouse gas footprint of the facility, covering direct Scope 1 emissions from on-site fuel combustion and indirect Scope 2 emissions from purchased electricity.